About this service
A structural steel in operation rarely corresponds to the original design. Years of use, expansions, added suspended loads, corrosion, and point interventions alter what was designed, and decisions about strengthening, changing the use, or installing equipment are made without reliable information. Structural engineering diagnostics assess the structure as it is and verify its real capacity for current and intended loads.
We apply a six-step method, from field survey to execution follow-up: inspect, diagnose, analyze, design, intervene and monitor. Each occurrence is measured, photographed and located on the drawing; the calculation model is rebuilt from real data and the capacity check follows NBR 8800. The result is a conclusion that withstands scrutiny from an insurer, an audit or an opposing expert.
Our experience ranges from small industrial sheds and mezzanines to a 30,600 m² industrial complex diagnosed in a single cycle, with the client's operation in full function. When the diagnosis indicates strengthening, the same team designs the solution, locating the intervention where it is necessary and utilizing the existing steel where capacity is available.
Signs that call for an assessment
These problems come up often in our site inspections and can almost always be fixed locally when identified early.
Purlins off the truss panel points
Load applied between panel points bends the top chord, which was designed to work in compression. The effect shows up as deformation and loosening of the connections.
Unstable bottom chord
Under wind uplift, the bottom chord goes into compression. Without enough lateral bracing, it buckles before reaching its design strength.
New hanging loads
Solar panels, ductwork, piping and hoists added after the design use up the structure's reserve capacity without anyone checking it.
Corrosion and section loss
The thickness measured in the field can be well below the nominal value. The check has to use the actual section, not the catalog section.
When to hire
- Before installing photovoltaic panels, conduits, ducts, or other loads on the roof
- When there is corrosion, visible deformations, loose connections, or buckling
- Before changing the use, expanding, or altering the overload of mezzanines and platforms
- After incidents: windstorm, fire, vehicle impact, or dropped load
- For regularization, insurance, financing, or asset audit
- When the structure does not have a project, or the project no longer represents what exists
What is included
- Geometric and dimensional survey
- Thickness and section loss measurement
- Pathology and joint mapping
- Capacity verification (NBR 8800)
- Analysis of suspended loads and photovoltaic panels
- Strengthening and adequacy project
- Technical report with ART
- As-built and structure technical file
What you receive
- Technical report with ART, describing method, observations, limitations, and conclusion
- Photographic record, with each occurrence located on the reference drawing
- Calculation report of capacity verification
- Strengthening design with executive detailing, when applicable
- As-built and technical file of the structure, for audits and insurance